OB415-S Meter in Steel Enclosure

OB415-S Meter in Steel Enclosure

OB415-S Meter in Steel Enclosure

MID Certified              SGS MID

OB415-S series is a fully MID UKCA certified single phase Active energy meter with pulse and backlit display.

Single phase Direct 100A metering - 4 DIN modules, Standard DIN rail format (DIN43880)

High Accuracy - EN50470 Class 1.0, MID Certified Annex B & D

  • Isolated pulse output

  • Large clear backlit display

Complete with Powder Coated Steel Enclosure

 

£55.00
Availability: Out of stock
SKU
OB415-S-STL
Single phase direct 100A metering - 4 DIN modules, Standard DIN rail Format (DIN43880) High Accuracy - EN50470 Class 1.0, MID Certified Annex B & D ● Isolated pulse output Large clear backlit display Benefits and Main Features > MID Certified Annex B &D > Single phase metering > Standard DIN rail Format (DIN43880) > CI.1 Accuracy (ENS0470) > Energy consumption LED, reverse current LED, > Communication LED > Isolated pulse output and IR (DIN43864) > LCD display, 6 integers 1 decimal > Clear backlit display > Internal transformer > Direct metering up to 100A > Memory back-up (EEprom) > 4 DIN modules > CE approval Technical data Voltage(v) 220/230V Operational voltage 70%-130%Un - Iref 10A -Itr 1A -Imax 100A -Imin 0.5A -Ist 40mA Power consumption of current circuits(VA) < 0.01 Power consumption of voltage circuits(W) < 1.3W General data Frequency (Hz) 50/60 Memory back-up EEprom Environment resistance to heat and fire Terminal 960℃ Cover 650℃ upper ABS+PC lower ABS+PC Pulse output Pulse width(ms) 80 Pulse constant(imp/kWh) 1600 Performance criteria Operating humidity ≤ 75% Storage humidity ≤ 95% Limit range of operating temperature -25°C - +55°C(3K6) Limit range for storage temperature -25°C - +55°C(1K4) Humidity 75% yearly average,95% on 30 days/year International standard EN50470-3 &IEC62053-21 Accuracy class CI.1 Protection against penetration of dust and water IP51
More Information
ModelOB415-S Meter in Steel Enclosure
ManufacturerOwen Brothers
In DepthVoltage(v) 220/230V Operational voltage 70%-130%Un - Iref 10A -Itr 1A -Imax 100A -Imin 0.5A -Ist 40mA Power consumption of current circuits(VA) < 0.01 Power consumption of voltage circuits(W) < 1.3W General data Frequency (Hz) 50/60 Memory back-up EEprom Environment resistance to heat and fire Terminal 960℃ Cover 650℃ upper ABS+PC lower ABS+PC Pulse output Pulse width(ms) 80 Pulse constant(imp/kWh) 1600 2 Performance criteria Operating humidity ≤ 75% Storage humidity ≤ 95% Limit range of operating temperature -25°C - +55°C(3K6) Limit range for storage temperature -25°C - +55°C(1K4) Humidity 75% yearly average,95% on 30 days/year International standard EN50470-3 &IEC62053-21 Accuracy class CI.1 Protection against penetration of dust and water IP51
Length15
Height15
Bredth6
HS Tariff CodeHS8536901000
Packing Buffer (in percentage)10
Packing TypeShared
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Trustpilot