OB415-S Meter in Steel Enclosure

OB415-S Meter in Steel Enclosure

OB415-S Meter in Steel Enclosure

MID Certified              SGS MID

OB415-S series is a fully MID UKCA certified single phase Active energy meter with pulse and backlit display.

Single phase Direct 100A metering - 4 DIN modules, Standard DIN rail format (DIN43880)

High Accuracy - EN50470 Class 1.0, MID Certified Annex B & D

  • Isolated pulse output

  • Large clear backlit display

Complete with Powder Coated Steel Enclosure

 

£55.00
Availability: Out of stock
SKU
OB415-S-STL
Single phase direct 100A metering - 4 DIN modules, Standard DIN rail Format (DIN43880) High Accuracy - EN50470 Class 1.0, MID Certified Annex B & D ● Isolated pulse output Large clear backlit display Benefits and Main Features > MID Certified Annex B &D > Single phase metering > Standard DIN rail Format (DIN43880) > CI.1 Accuracy (ENS0470) > Energy consumption LED, reverse current LED, > Communication LED > Isolated pulse output and IR (DIN43864) > LCD display, 6 integers 1 decimal > Clear backlit display > Internal transformer > Direct metering up to 100A > Memory back-up (EEprom) > 4 DIN modules > CE approval Technical data Voltage(v) 220/230V Operational voltage 70%-130%Un - Iref 10A -Itr 1A -Imax 100A -Imin 0.5A -Ist 40mA Power consumption of current circuits(VA) < 0.01 Power consumption of voltage circuits(W) < 1.3W General data Frequency (Hz) 50/60 Memory back-up EEprom Environment resistance to heat and fire Terminal 960℃ Cover 650℃ upper ABS+PC lower ABS+PC Pulse output Pulse width(ms) 80 Pulse constant(imp/kWh) 1600 Performance criteria Operating humidity ≤ 75% Storage humidity ≤ 95% Limit range of operating temperature -25°C - +55°C(3K6) Limit range for storage temperature -25°C - +55°C(1K4) Humidity 75% yearly average,95% on 30 days/year International standard EN50470-3 &IEC62053-21 Accuracy class CI.1 Protection against penetration of dust and water IP51
More Information
Model OB415-S Meter in Steel Enclosure
Manufacturer Owen Brothers
In Depth Voltage(v) 220/230V Operational voltage 70%-130%Un - Iref 10A -Itr 1A -Imax 100A -Imin 0.5A -Ist 40mA Power consumption of current circuits(VA) < 0.01 Power consumption of voltage circuits(W) < 1.3W General data Frequency (Hz) 50/60 Memory back-up EEprom Environment resistance to heat and fire Terminal 960℃ Cover 650℃ upper ABS+PC lower ABS+PC Pulse output Pulse width(ms) 80 Pulse constant(imp/kWh) 1600 2 Performance criteria Operating humidity ≤ 75% Storage humidity ≤ 95% Limit range of operating temperature -25°C - +55°C(3K6) Limit range for storage temperature -25°C - +55°C(1K4) Humidity 75% yearly average,95% on 30 days/year International standard EN50470-3 &IEC62053-21 Accuracy class CI.1 Protection against penetration of dust and water IP51
Length 15
Height 15
Bredth 6
HS Tariff Code HS8536901000
Packing Buffer (in percentage) 10
Packing Type Shared
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account