** NEW ** OB4374 Three Phase Multi Circuit Digital Meter - Rogowski Coils

** NEW ** OB4374 Three Phase Multi Circuit Digital Meter - Rogowski Coils

** NEW ** OB4374 Three Phase Multi Circuit Digital Meter - Rogowski Coils

      

The OB4374 meter supports three-phase three-wire, three-phase four-wire and single phase modes and can be configured for 6 single phases or 2 three phases and feature a plug-and-play RJ485 design making installation quick and easy.

Complete with 6 x Rogowski Coils and a 5m length cable.

Type: Three-phase CT operated, high-precision kWh meter, firmware upgradable, max/min/average demand, programmable digital output for loadshedding, export limitation, reverse relay, transformer metering, compatible with LV,MV, HV applications, harmonic analysis, phase sequence indication, allows CT/PT configuration, 5v DC output for communication equipment, dual source inputs for utility/generator measurement Class .1 accuracy with RS485 MODBUS RTU: baud rate, modbus ID, parity, Bi-directional, import/export, instant volt, amp, power factor, frequency, active power, reactive power, apparent power, programmable load survey/profile intervals, voltage asymmetry, true RMS measurements. Over 300+ parameters measured.

Housing: 4 DIN Module case

Usage: Suitable for renewables and solar PV

Nominal Input: Rogowski Coils - 400A, 600A, 1000A, 3000A

Voltage: 230V AC 50/60Hz

Output: SO Isolated pulsed output

Display: LCD Backlit display, voltage, ampere, kW, PF, Hz, + kWh, -kWh, total KWh

£307.20
Availability: In stock
SKU
OB4374CT-ROGO
** NEW ** OB4374 Three Phase Multi Circuit Digital Meter - Rogowski Coils is available to buy in increments of 1

      

The OB4374 meter supports three-phase three-wire, three-phase four-wire and single phase modes and can be configured for 6 single phases or 2 three phases and feature a plug-and-play RJ485 design making installation quick and easy.

Complete with 6 x Rogowski Coils and a 5m length cable.

Type: Three-phase CT operated, high-precision kWh meter, firmware upgradable, max/min/average demand, programmable digital output for loadshedding, export limitation, reverse relay, transformer metering, compatible with LV,MV, HV applications, harmonic analysis, phase sequence indication, allows CT/PT configuration, 5v DC output for communication equipment, dual source inputs for utility/generator measurement Class .1 accuracy with RS485 MODBUS RTU: baud rate, modbus ID, parity, Bi-directional, import/export, instant volt, amp, power factor, frequency, active power, reactive power, apparent power, programmable load survey/profile intervals, voltage asymmetry, true RMS measurements. Over 300+ parameters measured.

Housing: 4 DIN Module case

Usage: Suitable for renewables and solar PV

Nominal Input: Rogowski Coils - 400A, 600A, 1000A, 3000A

Voltage: 230V AC 50/60Hz

Output: SO Isolated pulsed output

Display: LCD Backlit display, voltage, ampere, kW, PF, Hz, + kWh, -kWh, total KWh

More Information
ModelOB4374 Three Phase Digital Meter with Dual Sensor - Rogowski Coils
Length20
Height20
Bredth15
HS Tariff Code9030310000
Packing Buffer (in percentage)10
Packing TypeIndividual
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Trustpilot